2024年2月15日发(作者:华为即将发布的新品)
SUN2000-375W-USP0 Smart PV Optimizer
User Manual
Issue
Date
04
2019-07-05
HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website:
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. i
SUN2000-375W-USP0 Smart PV Optimizer
User Manual About This Document
About This Document
Purpose
This document describes the SUN2000-375W-USP0 smart photovoltaic (PV) optimizer in
terms of its functions, electrical properties, and structure.
Figures provided in this document are for reference only.
Intended Audience
This document is intended for:
Sales engineers
Technical support engineers
Maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to
personal injury.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. ii
SUN2000-375W-USP0 Smart PV Optimizer
User Manual About This Document
Symbol
Description
Calls attention to important information, best practices
and tips.
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.
Change History
Changes between document issues are cumulative. The latest document issue contains all
updates made in previous issues.
Issue 04 (2019-07-05)
Updated A Technical Specifications
Issue 03 (2018-08-08)
Updated 1 Safety Precautions
Issue 02 (2018-03-23)
Modified all structural diagrams in the document.
Issue 01 (2018-01-02)
This issue is the first official release.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. iii
SUN2000-375W-USP0 Smart PV Optimizer
User Manual Contents
Contents
About This Document .................................................................................................................... ii
1 Safety Precautions ......................................................................................................................... 1
2 Overview ......................................................................................................................................... 4
2.1 Product Overview ......................................................................................................................................................... 4
2.2 4
2.3 Application Scenario ..................................................................................................................................................... 5
2.4 Model Naming Conventions ......................................................................................................................................... 6
2.5 Product Structure .......................................................................................................................................................... 6
3 8
3.1 Troubleshooting ............................................................................................................................................................ 8
3.2 Replacing a Optimizer .................................................................................................................................................. 9
A Technical Specifications ........................................................................................................... 10
B Acronyms and Abbreviations .................................................................................................. 15
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. iv
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 1 Safety Precautions
1
General Safety
Safety Precautions
Follow the precautions and special safety instructions provided by Huawei when
operating this product. Personnel who plan to install or maintain Huawei devices must
receive a thorough training, understand all necessary safety precautions, and be able to
correctly perform all operations. Huawei will not be liable for any consequences that are
caused by the violation of general safety regulations and device usage safety standards.
Before performing operations, read through this manual and follow all the precautions to
prevent accidents. The "DANGER", "WARNING", "CAUTION", and "NOTICE"
statements in this document do not represent all the safety instructions. They are only
supplements to the safety instructions.
Operation personnel should comply with local laws and regulations. The safety
instructions in this document are only supplements to local laws and regulations.
Do not operate the product or handle cables during thunderstorms.
Before operating the product, remove any conductors such as jewelry or watches.
Use insulated tools during operations.
Bolts should be tightened with a torque wrench and marked using red or blue color.
Installation personnel should mark tightened bolts in blue. Quality inspection personnel
should confirm if the bolts are tightened and then mark them in red. If screws or bolts
used to secure the device are not tightened to the required torque, the device may fall
from the mounting bracket.
Follow specified procedures during installation and maintenance. Do not attempt to alter
the device or deviate from the recommended installation procedures without prior
consent from the manufacturer.
Install the product in strict accordance with the quick guide.
If the optimizer needs to mounted onto a PV module frame, use the
TSM-XXXDD05A(II), TSMXXXDD05A.05(II), TSM-XXXDD05A.08(II), or
TSM-xxxPD05.50 series PV modules from Trina Solar Co., Ltd.
If the optimizer needs to be mounted onto a PV module support, ensure that the opening
width of the support is 10.5–14.0 mm and the thickness is 3–7 mm.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains important instructions for Models
SUN2000-375W-USP0 that shall be followed during installation and maintenance of the
optimizer.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 1
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 1 Safety Precautions
Disclaimer
Huawei shall not be liable for any consequence caused by any of the following events:
Transportation damage
The storage conditions do not meet the requirements specified in this document.
Incorrect installation or use
Installation or use by unqualified personnel
Failure to obey the operation instructions and safety precautions in this document
Operation in extreme environments which are not covered in this document
The optimizer operates beyond specified ranges.
Unauthorized modifications to the product or software code or removal of the product
Device damage due to force majeure (such as fire, and storm)
The warranty expires and the warranty service is not extended
Installation or use in environments which are not specified in related international
standards
Personnel Requirements
Only certified electricians areallowed to install, connect cables for, maintain, troubleshoot,
andreplace the optimizer.
Operation personnel should receive professional training.
Operation personnel should read through this document and follow all the precautions.
Operation personnel should be familiar with the safety specifications about the electrical
system.
Operation personnel should understand the composition and working principles of the
grid-tied PV power system and local regulations.
Operation personnel must wear proper personal protective equipment (PPE).
Protect Labels
Do notscrawl or damage any warning labels on the optimizer because theselabels contain
important information about safe operation.
Do notscrawl or damage the nameplate on the back of the optimizer becauseit contains
important product information.
Installation
Ensurethat the optimizer is not connected to a power supply or powered onbefore
finishing installation.
To allowproper heat dissipation and installation, maintain appropriate clearancesbetween
the optimizer and other objects.
Electrical Connections
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 2
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 1 Safety Precautions
Before connecting cables, ensure that the optimizer is not damagedin any way. Otherwise,
electric shocks or fire may occur.
Ensure that all electrical connections comply with local electrical standards.
Ensure that the cables used in a grid-tied PV system are properly connected and insulated
and meet all specification requirements.
The output wiring terminals of the optimizer cannot be hot swapped. If the terminals are
hot swapped, the optimizer may be damaged.
Operation
High voltagemay cause an electric shock, which results in serious injury, death,or serious
property damage from the optimizer in operation. Strictlycomply with the safety precautions
in this document and associateddocuments when operating the optimizer.
Donot touch an energized optimizer because it has a high temperature.
Follow local laws and regulations when operating the device.
Maintenance and Replacement
High voltage may cause an electric shock, which results in seriousinjury, death, or serious
property damage from the optimizer in ore, before maintenance, power off
the optimizer and strictlycomply with the safety precautions in this document and
associateddocuments to operate the optimizer.
Maintain the optimizer with sufficient knowledge of this document and propertools and
testing devices.
Temporary warning signs or fences must be placed to prevent unauthorized people from
entering the site.
The optimizer can be powered on only after all faults are rectified. Failingto do so may
escalate faults or damage the device.
During the maintenance, observe ESD precautions and wear ESD gloves.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 3
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 2 Overview
2
2.1 Product Overview
Figure 2-1 Optimizer
Overview
The optimizer is a DC-DC converter installed on the back of PV modules in a PV system. It
tracks the maximum power point (MPP) of each PV module to improve the energy yield of
the PV system, and performs the functions of module-level shutdown, module-level
monitoring, and automatic positioning.
2.2 Working Principles
Conceptual Diagram
The input port of the optimizer connects to the PV module. Through a DC/DC circuit, the PV
input voltage is converted into a required voltage and the maximum power point tracking
(MPPT) function is implemented.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 4
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 2 Overview
Figure 2-2 Conceptual diagram
Functions
Module-level MPPT: The optimizer improves the energy yield of the PV system by
continuously tracking the MPP of each PV module.
Module-level shutdown: The optimizer cuts off the voltage of each PV module.
Module-level monitoring: The optimizer monitors the operating status of each PV
module.
Automatic physical positioning: The optimizer determines the PV module location by
automatic physical positioning.
2.3 Application Scenario
The optimizer is mandatory and used for all PV modules. It performs the functions of MPPT,
module-level shutdown, monitoring, and automatic positioning.
Figure 2-3 Application scenario
(1) Inverter
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 5
SUN2000-375W-USP0 Smart PV Optimizer
User Manual
The inverter icon is for reference only.
2 Overview
2.4 Model Naming Conventions
Figure 2-4 Model naming conventions
2.5 Product Structure
Figure 2-5 Ports
(1) Output port (positive)
(3) Input port (negative)
(2) Output port (negative)
(4) Input port (positive)
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 6
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 2 Overview
Figure 2-6 Dimensions
(1) Mounting ear
Table 2-1 Label description
Label
Burn warning
Name
Electric shock warning
Direct current
Label Name
Grounding
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 7
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 3 System Maintenance
3
3.1 Troubleshooting
Alarm Name
Input overvoltage
Possible Cause
Overtemperature
System Maintenance
Table 3-1 Common alarms and troubleshooting measures
Troubleshooting Suggestion
The PV module output
1. Check whether the open-circuit
voltage of the PV modules connected
voltage exceeds the
to the SUN2000P exceeds 80 V.
maximum input voltage
of the SUN2000P. 2. Check whether the PV modules are
connected in series.
1. Check the ventilation and ambient
The ambient
temperature at the SUN2000P
temperature exceeds the
installation position. If the ventilation
upper threshold or the
is poor or the ambient temperature
SUN2000P is not
exceeds the upper threshold, improve
installed as required.
the ventilation and heat dissipation.
2. If the ventilation and ambient
temperature are normal, contact the
installation contractor.
A short circuit occurs
on the output of the
SUN2000P.
1. Check whether the inverter works
properly. If not, rectify the fault first.
2. Check that the output cable of the
SUN2000P is connected correctly.
3. Power off the system. Disconnect
cables on the input and output sides of
the SUN2000P after 5 minutes.
Reconnect them after 1 minute and
then power on the system. If the fault
persists, contact the installation
contractor.
Power off the system. Disconnect cables
on the input and output sides of the
SUN2000P after 5 minutes. Reconnect
them after 1 minute and then power on
the system. If the fault persists, contact
the installation contractor.
Output short circuit
Internal hardware
fault
The SUN2000P is not
properly installed or is
faulty.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 8
SUN2000-375W-USP0 Smart PV Optimizer
User Manual 3 System Maintenance
Contact the installation vendor if all failure analysis procedures listed above are completed and the fault
still exists.
3.2 Replacing a Optimizer
Prerequisites
The protective gloves and socket wrench are available.
A new optimizer is available.
Procedure
Step 1 Put on the protective gloves.
Step 2 Power off the inverter.
Step 3 Disconnect the input terminal of the optimizer.
Step 4 Remove the faulty optimizer.
1. Record the cable connection positions on the optimizer and disconnect the cables.
2. Unscrew the optimizer.
Step 5 Install the new optimizer.
1. Secure the new optimizer to the appropriate position, and tighten the bolt.
2. Connect the cables to the new optimizer based on the recorded information.
Step 6 Power on the inverter.
Step 7 Take off the protective gloves.
----End
Follow-up Procedure
Pack the faulty component and send it to the local Huawei warehouse.
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 9
SUN2000-375W-USP0 Smart PV Optimizer
User Manual A Technical Specifications
A
Environmental Specifications
Item
Operating temperature
Storage temperature
Relative humidity
Altitude
Technical Specifications
Table A-1 Environmental specifications
Specifications
–40°C to +85°C
–40°C to +85°C
0%–100% RH
0–4000 m
(When the altitude ranges from 2000 m to 4000 m, the
ambient temperature decreases by 0.7°C for each
additional 100 m.)
Electrical Specifications
Table A-2 Electrical specifications
Item
DC input
Specifications
Input voltage
Maximum input current
Maximum input power
DC output Output voltage range
Maximum output current
Efficiency
DC input
protection
Maximum efficiency
Input overvoltage protection threshold
Input overvoltage recovery threshold
10–80 V DC
12 A
375 W
4–80 V DC
15 A
99.5%
82–87 V DC
81–86 V DC
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 10
SUN2000-375W-USP0 Smart PV Optimizer
User Manual A Technical Specifications
Item Specifications
Input undervoltage protection threshold
Input undervoltage recovery threshold
7–9 V DC
8–10 V DC
85–90 V DC
Supported
3 million hours (Telcordia
SR-332 Method 1)
25 years
DC output
protection
Reliability
requirements
Protection
level
Safety
design
Output overvoltage protection threshold
Output overcurrent protection
Mean time between failures (MTBF)
Design life
NEMA TYPE 6P
UL1741
Figure A-2 Iin_max-Ta relationship curve
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 11
SUN2000-375W-USP0 Smart PV Optimizer
User Manual A Technical Specifications
Figure A-3 Pin_max-Ta relationship curve
Figure A-4 Pin_max-Vin relationship curve
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 12
SUN2000-375W-USP0 Smart PV Optimizer
User Manual A Technical Specifications
Figure A-5 Iin_max-Pin relationship curve (65°C)
Figure A-6 Iin_max-Pin relationship curve (85°C)
EMC Specifications
Table A-3 EMC specifications
Item
Electromagnetic
interference (EMI)
Specifications
Radiated emission (RE) FCC Part 15 Class B
ICES 003
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 13
SUN2000-375W-USP0 Smart PV Optimizer
User Manual A Technical Specifications
Item
Electromagnetic
susceptibility (EMS)
Specifications
ESD IEC61000-4-2
Contact discharge: ±6 kV,
criterion B
Air discharge: ±8 kV,
criterion B
Electrical fast transient (EFT)
Radiated susceptibility (RS)
Conducted susceptibility (CS)
Surge susceptibility
IEC61000-4-4, ±2 kV,
criterion B
IEC61000-4-3, criterion A
10 V/m field strength
IEC61000-4-6, criterion A
Power port: 10 V
IEC61000-4-5
Common mode: 2 kV
Structural Specifications
Table A-4 Structural specifications
Item
Installation mode
Dimensions (H x W
x D)
Specifications
Hung on a PV module support or PV module frame
3.35 in. x 5.31 in. x 0.99 in. (85 mm x 135 mm x 25.2 mm)±0.02
in. (0.5 mm), excluding the mounting ears and waterproof
terminals)
5.90 in. x 5.31 in. x 0.99 in. (150 mm x 135 mm x 25.2
mm)±0.02 in. (0.5 mm), including the mounting ears and
waterproof terminals)
Net weight 0.75 kg
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 14
SUN2000-375W-USP0 Smart PV Optimizer
User Manual B Acronyms and Abbreviations
B
D
DC
E
EFT
EMI
EMS
ESD
M
MPPT
R
RE
RS
Acronyms and Abbreviations
direct current
electrical fast transient
electromagnetic interference
electromagnetic susceptibility
electrostatic discharge
maximum power point tracking
radiated emission
radiated susceptibility
Issue 04 (2019-07-05) Copyright © Huawei Technologies Co., Ltd. 15
发布者:admin,转转请注明出处:http://www.yc00.com/num/1707957394a1532642.html