东丽TM700D系列高脱盐率苦咸水反渗透膜元件产品规格书说明书

东丽TM700D系列高脱盐率苦咸水反渗透膜元件产品规格书说明书


2024年4月17日发(作者:华为手机怎么录屏)

Product Datasheet

TM700D Series

High-Rejection Brackish Water Reverse Osmosis Membrane

Element with Enhanced Chemical Tolerance

Toray's reverse osmosis membrane technology applies decades

of R&D and precision automated manufacturing under ISO 9001

for consistency in product quality. State-of-the-art cross-linked

fully aromatic polyamide composite membranes produce high-

quality permeate and robust membrane chemistry for improved

performance and longer membrane life.

Product Specifi cations

Size

Membrane Area

Nominal Salt Rejection

Minimum Salt Rejection

Product Flow Rate

Minimum Product Flow Rate

Feed spacer thickness

Unit

ft² (m²)

%

%

gpd (m³/d)

gpd (m³/d)

mil

TM710D

4040

87 (8)

99.8

99.65

2,600 (9.8)

2,150 (8.2)

34

TM720D-400

8040

400 (37)

99.8

99.65

11,000 (41.6)

8,900 (33.6)

34

TM720D-440

8040

440 (41)

99.8

99.65

12,100 (45.8)

9,800 (37.0)

28

Test Conditions: Feed water pressure 225 psi (1.55 MPa); Feed water temperature 77 °F (25°C); Feed water concentration 2,000

mg/L as NaCl; Recovery rate 15%; Feed water pH 7

Applications

Municipal drinking water, Industrial process water,

Water reuse

Feed WaterPermeate

Products manufactured at our U.S.

facility (TMUS) are certifi ed to NSF/ANSI

61 for drinking water applications.

Concentrated Brine

Flow direction

Figure 1: 4040 elements

Dimensions in. (mm)

Size40408040

C

D

B

Figure 2: 8040 elements

A

A

B

C

D

4.0 (101)

40 (1,016)

0.75 (19)

1.05 (26)

7.9 (201)

40 (1,016)

1.125 (29)

A

D

C

B

1 of 2

01-MB1-01-230113

Product Datasheet

TM700D Series

Maximum operating pressure⁶

Maximum feed water temperature

Maximum feed water SDI₁₅

Feed water chlorine concentration

Feed water pH range

Continuous operation

Chemical cleaning

High-Rejection Brackish Water Reverse Osmosis Membrane

Element with Enhanced Chemical Tolerance

psi (MPa)

°F (°C)

600 (4.1)

113 (45)

5

ppm< 0.1

2–11

1–13

Maximum pressure drop per element

Maximum pressure drop per vessel

psi (MPa)

psi (MPa)

15 (0.10)

50 (0.34)

Operating Information

1. Please consult the latest Toray technical bulletin, design guidelines, computer design

program, or call an application specialist for the recommended design range. Not strictly

following the operating limits stated in this bulletin will void and nullify the Limited Warranty.

All RO elements are wet tested treated with a 1 percent by weight sodium bisulfite storage

solution. Afterward, the RO elements are vacuum packed in oxygen barrier bags or treated

with a tested feed water solution, and then vacuum sealed in oxygen barrier bags with

deoxidant inside. Toray recommends flushing Toray RO elements for 30 to 60 minutes once

every two days with sufficient quality flushing water, such as pre-treated feed water, to

prevent biological growth during system shutdown. Please refer to the Toray RO Handling

Manual for suggested flushing water quality.

The presence of free chlorine and other oxidizing agents under certain conditions, such

as heavy metals that act as oxidation catalysts in the feed water, will cause unexpected

oxidation of the membrane. Toray strongly recommends removing these oxidizing agents

contained in feed water before operating the RO system.

Permeate from the first hour of operation shall be discarded.

The customer is fully responsible for the effects of chemicals that are incompatible with the

elements. Their use will void the element Limited Warranty.

Maximum operating pressure will vary depending on feed temperature. Please ask for

detailed information from Toray if needed.

2.

Toray accepts no responsibility for results

obtained by the application of this information or

the safety or suitability of Toray's products, either

alone or in combination with other products.

Users are advised to make their own tests to

determine the safety and suitability of each

product combination for their own purposes.

All data may change without prior notice, due to

technical modifications or production changes.

Please be sure to inquire about the latest product

specifications.

3.

4.

5.

6.

2 of 2

01-MB1-01-230113

info@ Tel. +31-152-610-900

Fax. +31-152-616-289


发布者:admin,转转请注明出处:http://www.yc00.com/num/1713354022a2232248.html

相关推荐

发表回复

评论列表(0条)

  • 暂无评论

联系我们

400-800-8888

在线咨询: QQ交谈

邮件:admin@example.com

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信