Exadata硬件检查

Exadata硬件检查


2024年1月12日发(作者:)

Exadata硬件检查

一、 检查数据库服务器状态

1、

检查ilom状态有没有部件报错,正常输出为空。

# ipmitool sunoem cli "show faulty"

-> show faulty

Target | Property | Value

--------------------+------------------------+---------------------------------

-> Session closed

Disconnected

2、

检查硬盘状态,正常都为online,spun up

# /opt/MegaRAID/MegaCli/MegaCli64 -Pdlist -a0 | grep "Slot|Firmware state"

Slot Number: 0

Firmware state: Online, Spun Up

Slot Number: 1

Firmware state: Online, Spun Up

Slot Number: 2

Firmware state: Online, Spun Up

Slot Number: 3

Firmware state: Online, Spun Up

3、

检查硬件raid状态,正常为optimal

# /opt/MegaRAID/MegaCli/MegaCli64 -LdInfo -lAll -aAll

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)

Name :DBSYS

RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3

Size : 1.633 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 557.861 GB

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 4

Span Depth : 1

Creation Date : 04-02-2015

Creation Time : 02:36:39 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if

Bad BBU

Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache

if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Exit Code: 0x00

4、检查硬件firmware状态,正常为success

#

/opt/tTools/CheckHWnFWProfile -c strict

[SUCCESS] The hardware and firmware matches supported profile for

server=ORACLE_SERVER_X5-2

5、检查Infiniband网络状态,正常都为success

# /opt/tTools/ibdiagtools/verify-topology

[ DB Machine Infiniband Cabling Topology Verification Tool ]

Every node is connected to two leaf switches in a single

[SUCCESS]

Every inter-leaf switch link is connected correctly in a single

[SUCCESS]

Every leaf switch in an interconnected quarter rack is correctly connected to other rack in a

[NOT APPLICABLE]

Every leaf switch is connected to every spine switch in a multi-rack

[NOT APPLICABLE]

Every rack has balanced inter-leaf-and-spine switch links in a multi-rack

.[NOT APPLICABLE]

No spine switch is connected to another spine switch in a multi-rack

[NOT APPLICABLE]

Every spine switch is connected to two external spine switches in a multi-rack

[NOT APPLICABLE]

No external spine switch is connected to a leaf switch in a multi-rack

[NOT APPLICABLE]

No external spine switch is connected to another external spine switch in a multi-rack

[NOT APPLICABLE]

6、检查RAID卡上的电池状态,正常Battery State为Optimail。

# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0

BBU status for Adapter: 0

BatteryType: CVPM02

Voltage: 10694 mV

Current: 0 mA

Temperature: 18 C

Battery State: Optimal

BBU Firmware Status:

Charging Status : None

Voltage : OK

Temperature : OK

Learn Cycle Requested : No

Learn Cycle Active : No

Learn Cycle Status : OK

Learn Cycle Timeout : No

I2c Errors Detected : No

Battery Pack Missing : No

Battery Replacement required : No

Remaining Capacity Low : No

Periodic Learn Required : No

Transparent Learn : No

No space to cache offload : No

Pack is about to fail & should be replaced : No

Cache Offload premium feature required : No

Module microcode update required : No

Pack energy : 342 J

Capacitance : 110

Remaining reserve space : 0

Battery backup charge time : 0 hours

BBU Design Info for Adapter: 0

Date of Manufacture: 09/12, 2014

Design Capacity: 288 J

Design Voltage: 9500 mV

Serial Number: 18222

Manufacture Name: LSI

Firmware Version : 6071-04A

Device Name: CVPM02

Device Chemistry: EDLC

Battery FRU: N/A

TMM FRU: N/A

Module Version = 6071-04A

Transparent Learn = 1

App Data = 0

BBU Properties for Adapter: 0

Auto Learn Period: 28 Days

Next Learn time: Wed Sep 2 15:06:36 2015

Learn Delay Interval:0 Hours

Auto-Learn Mode: Transparent

Exit Code: 0x00

7、检查文件系统使用率没有超过90%甚至100%

# df -h

Filesystem Size Used Avail Use% Mounted on

/dev/mapper/VGExaDb-LVDbSys1

30G 27G 1.2G 97% /

tmpfs 252G 633M 252G 1% /dev/shm

/dev/sda1 504M 40M 439M 9% /boot

/dev/mapper/VGExaDb-LVDbOra1

99G 23G 72G 24% /u01

8、检查光纤网口的状态,Link detected 为yes

# ethtool eth4

Settings for eth4:

Supported ports: [ FIBRE ]

Supported link modes: 1000baseT/Full

10000baseT/Full

Supported pause frame use: No

Supports auto-negotiation: Yes

Advertised link modes: 1000baseT/Full

10000baseT/Full

Advertised pause frame use: No

Advertised auto-negotiation: Yes

Speed: 1000Mb/s

Duplex: Full

Port: FIBRE

PHYAD: 0

Transceiver: external

Auto-negotiation: on

Supports Wake-on: d

Wake-on: d

Current message level: 0x00000007 (7)

drv probe link

Link detected: yes

# ethtool eth5

Settings for eth5:

Supported ports: [ FIBRE ]

Supported link modes: 1000baseT/Full

10000baseT/Full

Supported pause frame use: No

Supports auto-negotiation: Yes

Advertised link modes: 1000baseT/Full

10000baseT/Full

Advertised pause frame use: No

Advertised auto-negotiation: Yes

Speed: 1000Mb/s

Duplex: Full

Port: FIBRE

PHYAD: 0

Transceiver: external

Auto-negotiation: on

Supports Wake-on: d

Wake-on: d

Current message level: 0x00000007 (7)

drv probe link

Link detected: yes

9、检查Infiniband网口的状态,正常状态为Active & LinkUp

# ibstatus

Infiniband device 'mlx4_0' port 1 status:

default gid: fe80:0000:0000:0000:0010:e000:0148:1e79

base lid: 0x3

sm lid: 0x2

state: 4: ACTIVE

phys state: 5: LinkUp

rate: 40 Gb/sec (4X QDR)

link_layer: IB

Infiniband device 'mlx4_0' port 2 status:

default gid: fe80:0000:0000:0000:0010:e000:0148:1e7a

base lid: 0x4

sm lid: 0x2

state: 4: ACTIVE

phys state: 5: LinkUp

rate: 40 Gb/sec (4X QDR)

link_layer: IB

二、 检查存储服务器状态

1、 检查ilom状态有没有部件报错,正常输出为空。

# ipmitool sunoem cli "show faulty"

-> show faulty

Target | Property | Value

--------------------+------------------------+---------------------------------

-> Session closed

Disconnected

2、 检查硬盘状态,正常都为online,spun up

# /opt/MegaRAID/MegaCli/MegaCli64 -Pdlist -a0 | grep "Slot|Firmware state"

Slot Number: 0

Firmware state: Online, Spun Up

Slot Number: 1

Firmware state: Online, Spun Up

Slot Number: 2

Firmware state: Online, Spun Up

Slot Number: 3

Firmware state: Online, Spun Up

Slot Number: 4

Firmware state: Online, Spun Up

Slot Number: 5

Firmware state: Online, Spun Up

Slot Number: 6

Firmware state: Online, Spun Up

Slot Number: 7

Firmware state: Online, Spun Up

Slot Number: 8

Firmware state: Online, Spun Up

Slot Number: 9

Firmware state: Online, Spun Up

Slot Number: 10

Firmware state: Online, Spun Up

Slot Number: 11

Firmware state: Online, Spun Up

3、 检查硬件raid状态,正常为optimal

# /opt/MegaRAID/MegaCli/MegaCli64 -LdInfo -lAll -aAll

Adapter 0 -- Virtual Drive Information:

Virtual Drive: 0 (Target Id: 0)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:40 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 1 (Target Id: 1)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:41 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 2 (Target Id: 2)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:41 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 3 (Target Id: 3)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:41 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 4 (Target Id: 4)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:42 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 5 (Target Id: 5)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:42 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 6 (Target Id: 6)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:43 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 7 (Target Id: 7)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:43 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 8 (Target Id: 8)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:44 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 9 (Target Id: 9)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:44 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 10 (Target Id: 10)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:45 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Virtual Drive: 11 (Target Id: 11)

Name :

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

Size : 3.637 TB

Physical Sector Size: 512

Logical Sector Size : 512

VD has Emulated PD : No

Parity Size : 0

State : Optimal

Strip Size : 1.0 MB

Number Of Drives : 1

Span Depth : 1

Creation Date : 05-08-2015

Creation Time : 03:45:45 PM

Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

Default Access Policy: Read/Write

Current Access Policy: Read/Write

Disk Cache Policy : Disabled

Encryption Type : None

Bad Blocks Exist: No

PI type: No PI

Is VD Cached: No

Exit Code: 0x00

4、检查硬件firmware状态,正常为success

#

/opt/tTools/CheckHWnFWProfile -c strict

[SUCCESS] The hardware and firmware matches supported profile for

server=ORACLE_SERVER_X5-2L

5、检查Infiniband网络状态,正常都为success

# /opt/tTools/ibdiagtools/verify-topology

[ DB Machine Infiniband Cabling Topology Verification Tool ]

Every node is connected to two leaf switches in a single

[SUCCESS]

Every inter-leaf switch link is connected correctly in a single

[SUCCESS]

Every leaf switch in an interconnected quarter rack is correctly connected to other rack in a

[NOT APPLICABLE]

Every leaf switch is connected to every spine switch in a multi-rack

[NOT APPLICABLE]

Every rack has balanced inter-leaf-and-spine switch links in a multi-rack

.[NOT APPLICABLE]

No spine switch is connected to another spine switch in a multi-rack

[NOT APPLICABLE]

Every spine switch is connected to two external spine switches in a multi-rack

[NOT APPLICABLE]

No external spine switch is connected to a leaf switch in a multi-rack

[NOT APPLICABLE]

No external spine switch is connected to another external spine switch in a multi-rack

[NOT APPLICABLE]

6、检查RAID卡上的电池状态,正常Battery State为Optimal。

# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0

BBU status for Adapter: 0

BatteryType: CVPM02

Voltage: 9449 mV

Current: 0 mA

Temperature: 28 C

Battery State: Optimal

BBU Firmware Status:

Charging Status : None

Voltage : OK

Temperature : OK

Learn Cycle Requested : No

Learn Cycle Active : No

Learn Cycle Status : OK

Learn Cycle Timeout : No

I2c Errors Detected : No

Battery Pack Missing : No

Battery Replacement required : No

Remaining Capacity Low : No

Periodic Learn Required : No

Transparent Learn : No

No space to cache offload : No

Pack is about to fail & should be replaced : No

Cache Offload premium feature required : No

Module microcode update required : No

Pack energy : 248 J

Capacitance : 110

Remaining reserve space : 0

Battery backup charge time : 0 hours

BBU Design Info for Adapter: 0

Date of Manufacture: 11/04, 2014

Design Capacity: 288 J

Design Voltage: 9500 mV

Serial Number: 235

Manufacture Name: LSI

Firmware Version : 6071-04A

Device Name: CVPM02

Device Chemistry: EDLC

Battery FRU: N/A

TMM FRU: N/A

Module Version = 6071-04A

Transparent Learn = 1

App Data = 0

BBU Properties for Adapter: 0

Auto Learn Period: 28 Days

Next Learn time: Wed Sep 2 15:03:20 2015

Learn Delay Interval:0 Hours

Auto-Learn Mode: Transparent

Exit Code: 0x00

7、检查文件系统使用率没有超过90%甚至100%

# df -h

Filesystem Size Used Avail Use% Mounted on

/dev/md5 9.9G 5.3G 4.1G 57% /

tmpfs 48G 4.0K 48G 1% /dev/shm

/dev/md7 3.0G 1.6G 1.3G 56% /opt/oracle

/dev/md4 114M 26M 83M 24% /boot

/dev/md11 5.0G 156M 4.6G 4% /var/log/oracle

8、检查系统盘镜像状态都为active

# mdadm --detail /dev/md* | grep State

State : clean

State : clean

State : clean

State : clean

State : clean

State : clean

State : clean

State : clean

9、检查本地硬盘和flash硬盘的状态,正常都为noraml

# cellcli -e list physicaldisk

8:0 E0LU7X normal

8:1 E1Y29X normal

8:2 EZBN5X normal

8:3 E1UYGX normal

8:4 E07GRX normal

8:5 E20A5X normal

8:6 E0LTHX normal

8:7 E0LSWX normal

8:8 E0LS2X normal

8:9 E07DXX normal

8:10 E1NKDX normal

8:11 ES8AYX normal

FLASH_1_1 CVMD4512002N1P6KGN normal

FLASH_2_1 CVMD4511007F1P6KGN normal

FLASH_4_1 CVMD451600KZ1P6KGN normal

FLASH_5_1 CVMD451600EY1P6KGN normal

10、检查griddisk的状态都为online和active

# cellcli -e list griddisk attributes name, asmmodestatus,

asmdeactivationoutcome

DATA_DM01_CD_00_dm01celadm01 ONLINE Yes

DATA_DM01_CD_01_dm01celadm01 ONLINE Yes

DATA_DM01_CD_02_dm01celadm01 ONLINE Yes

DATA_DM01_CD_03_dm01celadm01 ONLINE Yes

DATA_DM01_CD_04_dm01celadm01 ONLINE Yes

DATA_DM01_CD_05_dm01celadm01 ONLINE Yes

DBFS_DG_CD_02_dm01celadm01 ONLINE Yes

DBFS_DG_CD_03_dm01celadm01 ONLINE Yes

DBFS_DG_CD_04_dm01celadm01 ONLINE Yes

DBFS_DG_CD_05_dm01celadm01 ONLINE Yes

RECO_DM01_CD_00_dm01celadm01 ONLINE Yes

RECO_DM01_CD_01_dm01celadm01 ONLINE Yes

RECO_DM01_CD_02_dm01celadm01 ONLINE Yes

RECO_DM01_CD_03_dm01celadm01 ONLINE Yes

RECO_DM01_CD_04_dm01celadm01 ONLINE Yes

RECO_DM01_CD_05_dm01celadm01 ONLINE Yes

11、检查Infiniband网口的状态,正常状态为Active & LinkUp

# ibstatus

Infiniband device 'mlx4_0' port 1 status:

default gid: fe80:0000:0000:0000:0010:e000:0166:1665

base lid: 0x9

sm lid: 0x2

state: 4: ACTIVE

phys state: 5: LinkUp

rate: 40 Gb/sec (4X QDR)

link_layer: IB

Infiniband device 'mlx4_0' port 2 status:

default gid: fe80:0000:0000:0000:0010:e000:0166:1666

base lid: 0xa

sm lid: 0x2

state: 4: ACTIVE

phys state: 5: LinkUp

rate: 40 Gb/sec (4X QDR)

link_layer: IB

三、

检查Infiniband交换机状态

# showunhealthy

OK - No unhealthy sensors

# env_test

Environment test started:

Starting Environment Daemon test:

Environment daemon running

Environment Daemon test returned OK

Starting Voltage test:

Voltage ECB OK

Measured 3.3V Main = 3.27 V

Measured 3.3V Standby = 3.37 V

Measured 12V = 11.97 V

Measured 5V = 5.07 V

Measured VBAT = 3.01 V

Measured 2.5V = 2.52 V

Measured 1.8V = 1.78 V

Measured I4 1.2V = 1.22 V

Voltage test returned OK

Starting PSU test:

PSU 0 present OK

PSU 1 present OK

PSU test returned OK

Starting Temperature test:

Back temperature 27

Front temperature 28

SP temperature 46

Switch temperature 44, maxtemperature 44

Temperature test returned OK

Starting FAN test:

Fan 0 not present

Fan 1 running at rpm 11445

Fan 2 running at rpm 11336

Fan 3 running at rpm 11336

Fan 4 not present

FAN test returned OK

Starting Connector test:

Connector test returned OK

Starting Onboard ibdevice test:

Switch OK

All Internal ibdevices OK

Onboard ibdevice test returned OK

Starting SSD test:

SSD test returned OK

Environment test PASSED

# setsmpriority list

Current SM settings:

smpriority 5

controlled_handover TRUE

subnet_prefix 0xfe80

M_Key None

Routing engine FatTree

四、 检查Cisco交换机状态,电源、风扇都为good。

# show environment

no temperature alarms

Module Sensor Temperature Status

------+--------------------------+--------------------+------------

1 air inlet 36C (58C,73C,76C) ok

1 air outlet 38C (65C,81C,84C) ok

Power Fan Inline

Supply Model No Type Status Sensor Status

------ ---------------- --------- ----------- ------- -------

PS1 PWR-C49E-300AC-F AC 300W good good n.a.

PS2 PWR-C49E-300AC-F AC 300W good good n.a.

Power supplies needed by system : 1

Power supplies currently available : 2

Chassis Type : WS-C4948E-F

Power consumed by backplane : 0 Watts

Switch Bandwidth Utilization : 0%

Supervisor Led Color : Green

Module 1 Status Led Color : Green

Fantray : Good

Fantray removal timeout : 120

Power consumed by Fantray : 30 Watts

五、 故障数据收集

1、 ilom snapshot

运行:ilom-ip

iLom Administration --> Maintenance --> snapshot --> Run

输出:信息收集完成后会提示存放位置。

2、 sundiag

运行: /opt/tTools/

输出:在/tmp成生成sundiag*.2的文件


发布者:admin,转转请注明出处:http://www.yc00.com/news/1705051513a1388866.html